Operation – MacDon 872 Combine Adapter User Manual

Page 16

Advertising
background image

16

OPERATION

HEADER LEVELLING

Adjust header levelling with header at the flattest angle.
See Header Angle, below.
1. With header on level ground, lower header so

cutterbar is 2 to 4 inches (50 to 100 mm) off the
ground.

2. Check level of header by measuring cutterbar to

ground at both ends.

3. To lower cutterbar on one end, remove a shim (C)

from between rubber pads (D) and angle (E).
Adjust shim quantity side to side, placing from 0 to
2 shims to level header. To add or remove a shim:

Lower cutterbar to ground and continue lowering
feeder house so gap at (A) increases.

Remove nut (F) and add or remove shim(s) as

required.

Reassemble, maintaining 1/8 inch (3 mm) between
angle and float support as shown.

HEADER ANGLE
The header (or guard) angle can be adjusted from
15

°

to

20

°

below horizontal. (Actual angle may vary with

combine set-up.)
See Combine Operator’s Manual for header levelling
and additional header angle adjustments.

IMPORTANT: The flat header angle (15

°

) is

recommended for normal conditions. A flatter header
angle reduces sickle section breakage and reduces soil
scooping or build-up at the cutterbar in wet conditions.
Use a steeper angle to cut very close to the ground, or
in down crop for better lifting action.

IMPORTANT: Always check adapter drum clearance to header frame after adjusting header angle. Flattening
the header angle will reduce the clearance to the drum fingers.

IMPORTANT: Header flotation gets lighter as header
angle increases, and must be readjusted. See
"Header Flotation", on page 15.

To adjust header angle with mechanical link:
1. Lower cutterbar to ground and continue

lowering to drop feeder house another 2 to 5
inches (50 to 125 mm).

2. Back off the locking collar (A) on top link

turnbuckle.

3. Using a punch in hole in turnbuckle (B), turn to

adjust header angle.
Longer top link = steeper header angle

( = lighter float )

4. At desired adjustment, tighten locking collar (A)

securely against turnbuckle to fix the position.

HEADER ANGLE HYDRAULIC ADJUSTMENT

An optional kit is available which allows adjustment
of header angle from the combine cab by means
of a hydraulic cylinder.
See “Unloading and Assembly” section for
information on assembly and use of this option.

HEADER ANGLE MECHANICAL ADJUSTMENT

HEADER LEVELLING

Advertising