Adapter Mounting Instructions

for Cat Lexion Combines

ATTACHING ADAPTER TO COMBINE (continued)

4. Install pump as follows:

NOTE: Wear gloves when handling pump.

a. Remove pump from storage position (A) on adapter

and slide pump onto R/H feeder house output shaft.

NOTE: The first time the pump is installed, hoses
may have to be loosened for proper alignment.
Tighten hoses after installation.

b. Engage pump torque arm on support arm on

combine and secure with lynch pin at (B).

5. Tighten combine feeder chain and check

clearances.

PUMP STORAGE ON ADAPTER

A

PUMP IN WORKING POSITION

B

COMBINE TO HEADER CONNECTIONS –

RIGHT SIDE REEL DRIVE ON 972 SHOWN

DRAPER DRIVE HOSE CONNECTIONS – 962

Pass draper drive pressure hose (C) through
loop of reel lift hose at (D) to prevent hoses
dragging. Pass draper drive return hose (E)
between header and control box to connect at
adapter.

D

C

E

DRAPER DRIVE HOSE CONNECTIONS – 972

Draper drive pressure hose connects at (F)

F