Maintenance/service – MacDon 872 Combine Adapter User Manual

Page 23

Advertising
background image

23

MAINTENANCE/SERVICE

HYDRAULIC SYSTEM (continued)

Flow Control Relief Pressure
A possible cause of insufficient draper speed is
low relief pressure.
To check relief pressure:
1. Attach a 5000 psi (34.5 MPa) pressure gauge

in gauge port (GP) of valve block.

2. Install a needle valve between the orange

colour coded male coupler on adapter and the
orange colour coded female coupler on header.
NOTE: Using the needle valve built into the
valve block will not check relief pressure.

3. Set flow control knob to number 6 on dial.
4. Run combine engine at operating speed.
5. Engage header drive.
6. Close needle valve until flow stops. Pressure

reading should be 3100 psi (21.4 MPa).

WARNING: To avoid bodily injury
from bursting hoses and/or
exploding components, do not

exceed 3250 psi pressure (22.4 MPa). Do not
continue closing needle valve if pressure
exceeds 3250 psi (22.4 MPa).

If relief pressure requires adjustment:
1. Loosen jam nut (C).
2. Turn relief screw until relief pressure is correct.
3. Tighten jam nut.

GEARBOX LUBRICATION

Change gearbox oil every 1000 hours or 3 years.
Box capacity: 450 mL (15 U.S. oz.)

Lubricant: SAE 85W-140 gear lube (API Service Classification GL-5).

Breather plug – (B)
Level plug – (L)
Drain plug – (D)

FLOW CONTROL RELIEF ADJUSTMENT

GP

C

B

NH, JD Contour Master

CASE, GLEANER & JD

CAT LEXION

& JD 50 Series Level Land

Level Land prior to 50 Series

L

D

B

L

D

B

L

D