2.

Press the ENTER button to continue the program. The program displays the Alarm OFF Delay
screen.

•

Alarm Off Delay Screen
This screen indicates the length of time that the Pioneer-R16 delays turning off alarm indications
(buzzer and relays) after an alarm 1, alarm 2, or alarm 3 condition passes. You can choose from a range
of 0 Seconds to 60 Minutes. The default setting is 0 Minutes, 0 Seconds.

-

To accept the alarm off delay setting and continue the program, press the ENTER button. The
program displays the Relay Action screen.

-

To update the alarm off delay setting:
1.

Use the UP/YES and DOWN/NO buttons to display the setting you want.

2.

Press the ENTER button to continue the program. The program displays the Relay Action
screen.

•

Relay Action Screen
This screen indicates how the relays operate in normal and alarm conditions. If the setting is

NORMALLY DE-ENERGIZED

, the relays energize in alarm conditions. If the setting is

NORMALLY ENERGIZED

, the relays de-energize in alarm conditions. The default setting is

NORMALLY DE-ENERGIZED

.

N O T E

: The common fail relay and channel fail relay (if assigned) are not affected by this setting. Fail

relay(s) are factory-set as normally energized and are not adjustable.

-

To accept the relay action setting and continue the program, press the ENTER button. The
program displays the Alarm Logic screen.

-

To update the relay action setting:
1.

Use the UP/YES or DOWN/NO button to display the setting you want.

2.

Press the ENTER button to continue the program. The program displays the Alarm Logic
screen.

•

Alarm Logic Screen
This screen indicates how an alarm circuit is reset after the applicable alarm condition passes. If the
setting is

LATCHING

, you must press the reset switch after the alarm condition passes to reset the

alarm circuit. If the setting is

A U T O - R E S E T

, the alarm circuit is automatically reset after the alarm

condition passes. The default setting is

LATCHING

.