To accept the noise filter setting and continue the program, press the ENTER button. The
program displays the Number of Channels screen.

-

To update the noise filter setting:
1.

Use the UP/YES or DOWN/NO button to display the setting you want.

2.

Press the ENTER button to continue the program. The program displays the Number of
Channels screen.

Number of channels screen
This screen indicates the maximum number of channels possible for the Pioneer-R16. The maximum
number of channels possible is 16 (for a fully loaded subrack with four displays). This is factory set for
16 channels and if less than 16 are loaded, they unused channels may be deactivated in the Channel
Setup Program.

16

-

To accept the number of channels setting and continue the program, press the ENTER button.
The program displays the Zero Suppression screen.

-

To update the number of channels setting:
1.

Use the UP/YES or DOWN/NO button to display the setting you want.

2.

Press the ENTER button to continue the program. The program displays the Zero
Suppression screen.

Zero suppression screen
This screen indicates the zero suppression for the Pioneer-R16. The zero suppression feature helps
prevent “jumpy” readings near the normal reading. For example, if the zero suppression setting is
2.0% of fullscale and fullscale is 10.0 ppm, then the Pioneer will display a reading of 0.0 ppm for gas
readings from -0.2 to 0.2 ppm. You can choose from a range of 0.0% to 5.0% (in 0.1% increments).
The default setting is 2.0%.

-

To accept the zero suppression setting and continue the program, press the ENTER button. The
program displays the Instrument Label screen.

-

To update the zero suppression setting:
1.

Use the UP/YES or DOWN/NO button to display the setting you want.

2.

Press the ENTER button to continue the program. The program displays the Instrument
Label screen.

Instrument label screen
This screen indicates the identifying label for this Pioneer-R16. You can choose a label of up to 15
characters. Characters can be letters, numbers, symbols, or blank spaces. The default setting is RKI
INSTRUMENTS.