Speed”, and the maximum rate can reach to 100% of “Downlink Speed”.
Normal: guarantees that the minimum global rate of router is 10% of “Downlink
Speed”, and the maximum rate can reach to 100% of “Downlink Speed”.
Bulk: guarantees that the minimum global rate of router is 1% of “Downlink
Speed”, and the maximum rate can reach to 100% of “Downlink Speed”.

Optimize for Serial
Data Forwarding

Enable to optimize for serial data forwarding, which means serial data forwarding
will get the highest priority to occupy bandwidth.
When enable serial data forwarding it need to enable local port number for
controlling. Therefore, it needs to set local port number of router even if router is
as TCP Client.

Disable

Optimize for ICMP

Enable to optimize for ICMP, which means ICMP will get the highest priority to
occupy bandwidth. After enabled respond interval of PING control will be
shorter.
Note: if user click to enable “Optimize for TCP Flags”, “Optimize for Serial Data
Forwarding”, and “Optimize for ICMP” at the same time (these three services are
in the same priority level), router will automatically start Stochastic Fairness
Queueing (SFQ) strategy to make a fair bandwidth allocation, in case of one
service occupy all the bandwidth.

Disable

MAC Address @ QoS
MAC Control List

Enter MAC address of the user (for example, PC) who you want to set it with QoS
Control. Router supports up to 20 users set with QoS MAC Control. Priority of
QoS MAC Control is higher than that of QoS IP control.

Null

Priority @ QoS MAC
Control List

Select from “Exempt”, “Premium”, “Express”, “Normal” and “Bulk”.
Select the priority of the user (for example, PC) who you want to set it with QoS
Control.
Exempt: this is the highest priority which guarantees that the minimum global
rate of router is 50% of “Downlink Speed”, and the maximum rate can reach to
100% of “Downlink Speed”.
Premium: guarantees that the minimum global rate of router is 25% of “Downlink
Speed”, and the maximum rate can reach to 100% of “Downlink Speed”.
Express: guarantees that the minimum global rate of router is 15% of “Downlink
Speed”, and the maximum rate can reach to 100% of “Downlink Speed”.
Normal: guarantees that the minimum global rate of router is 10% of “Downlink
Speed”, and the maximum rate can reach to 100% of “Downlink Speed”.
Bulk: guarantees that the minimum global rate of router is 1% of “Downlink
Speed”, and the maximum rate can reach to 100% of “Downlink Speed”.

Exempt

IP Address @ QoS IP
Control List

Enter IP address of the user (for example, PC) who you want to set it with QoS
Control. Router supports up to 20 users set with QoS IP Control. If want to
control one network segment, user can set “IP Address” as format “x.x.x.x/24” or
“x.x.x.x/255.255.255.0”. For example, if we to control network segment “172.16.
x.x”, we can set “172.16.0.0/16” or “172.16.0.0/255.255.0.0” in “IP Address”.

Null

Priority @ QoS IP
Control List

Select from “Exempt”, “Premium”, “Express”, “Normal” and “Bulk”.
Select the priority of the user (for example, PC) who you want to set it with QoS
Control.