SERVICE (cont.)

OPTIONAL ELECTRONIC THERMOSTAT (ERT):

The ERT is located inside the trunk on the upper left

side of the component bracket.

Test Procedures:

1. Disconnect the brewer from the power source.

2. Gently remove the temperature sensor and grom-

met from the tank.

3. Check voltage across the blue wire from limit

thermostat and the white wire at the terminal

block. Connect the brewer to the power source.

The indication must be: 120Vac.

If voltage is not present as described, refer to the wiring

diagrams and check the brewer wiring harness

If voltage is present as described, proceed to #4.

4. Disconnect the brewer from the power source.

5. With the temperature sensor and grommet still out

of the tank, check voltage across the black wire

to the heater and the white wire at the terminal

block. Connect the brewer to the power source.

The indication must be: 120Vac.

If voltage is not present as described, replace ERT.

If voltage is present as described, the ERT is function-

ing properly.

Removal and Replacement:

1. Disconnect the control thermostat wires.

2. Remove the temperature sensor by firmly pulling-

up on the metal sheath at the tank lid. This will

disengage the grommet from the tank lid.

3. Remove the one #8-32 screw securing the ERT to

the component bracket inside the trunk.

4. Slide the grommet to the top of the sheath.

5. Insert the temperature sensor through the hole

in the tank lid and press the grommet firmly and

evenly so that the groove in the grommet fits into

the tank lid.

6. Using the #8-32 screw, secure the ERT to the

component bracket inside the trunk.

7. For first type thermostat, refer to Wiring Diagrams

when reconnecting ERT wires.

8. Adjust the ERT as required.

FIG 11-1 THERMOSTAT TERMINALS

First Type

Second Type

Third Type

41711.1 052009

ERT

NOTE: The ERT has a range of 170° - 210°F. Use care

not to set it too high or boiling could occur.