Bunn C User Manual

Page 17

Advertising
background image

Page 17

1800W-120V

7.40 - 8.70

1850W-220V

24.40 -28.40

3500W-200V

10.70 -12.36

3500W-240V

15.36 -17.90

HEATER RESISTANCE

If resistance is present as described, reconnect the

wires, the tank heater is ok.

If resistance is not present as described, replace the

tank heater.

NOTE

- If any resistance is read between sheath and

either terminal, remove and inspect heater for cracks

in the sheath.

Removal and Replacement:

1. Disconnect the water supply tube from the fill

basin.

2. Remove the tank inlet fitting securing the fill basin

to the tank lid, remove fill basin and tank inlet

gasket. Set all three parts aside for reassembly.

3. On brewers with faucet, shut-off water supply

to the brewer and disconnect the inlet and outlet

water lines to the faucet coil assembly.

4. Disconnect the black wire on the limit thermostat

from the tank heater switch. On late model brew-

ers also disconnect the blue wire from the limit

thermostat to the control thermostat.

5. Disconnect the black wire and the white or red

wire from the tank heater terminals.

6. Remove sprayhead and the hex nut securing the

sprayhead tube to the hood. Set aside for reas-

sembly.

7. Remove the eight #8-32 nuts securing the tank lid

to the tank.

8. Remove the tank lid with limit thermostat, spray-

head tube, tank heater, coil assembly and control

thermostat w/bracket (early models only).

9 Remove the two hex nuts securing the tank heater

to the tank lid. Remove tank heater with gaskets

and discard.

10. Install new tank heater with gaskets on the tank

lid and secure with two hex nuts.

SERVICE (cont.)

TANK HEATER (Cont.)

FIG. 17-2 TANK HEATER TERMINALS

11. Install tank lid with limit thermostat, sprayhead

tube, tank heater, coil assembly (brewers with

faucet) and control thermostat with bracket (early

brewers only) using eight #8-32 hex nut.

12. Reconnect the inlet and outlet water lines to the

faucet coil assembly.

13. Secure sprayhead tube to hood using a hex nut.

14. Install sprayhead.

15. Reconnect the wires to the limit thermostat, tank

heater and control thermostat. See limit thermostat

and control thermostat sections in this manual

when reconnecting wires.

16. Install fill basin, secure with tank inlet fitting and

gasket. Insert water supply line through grommet

in fill basin.

17. Refer to Fig.13 when reconnecting the tank heater

wires.

WHI to Terminal Block

(White Insert on 230V

Two Wire Models)

RED to Terminal Block

(Red Insert on 120/240V

Three Wire Models or

200V and 240V Two

Wire Models

BLK to Control Ther-

mostat (Brewers W/

Out Faucet)

Thermal Cut-Off to BLK

from Control Ther-

mostat (Brewers W/

Faucet)

41711.1 052009

FIG. 17-1 TANK HEATER RESISTANCE

TERMINAL TO SHEATH - INFINITE (OPEN)