Bunn C User Manual

Page 6

Advertising
background image

Page 6

TROUBLESHOOTING (cont.)

Inconsistent beverage level in

dispenser

Consistently low beverage level

in the dispenser

Spitting or excessive steaming

1. Strainer /flow control (.222

GPM) Early models.

2. Syphon System

3. Lime Build-up

CAUTION - Tank and tank

components should be delimed

regularly depending on local wa-

ter conditions. Excessive min-

eral build-up on stainless steel

surfaces can initiate corrosive

reactions resulting in serious

leaks.

4. Water Pressure

1. Timer

2. Strainer/flow Control (.222

GPM)

1. Lime Build-up

CAUTION - Tank and tank

components should be delimed

regularly depending on local wa-

ter conditions. Excessive min-

eral build-up on stainless steel

surfaces can initiate corrosive

reactions resulting in serious

leaks.

(A) Direction of flow arrow must

be pointing towards the brewer.

(B) Remove the strainer/flow

control and check for obstruc-

tion. Clear or replace.

The brewer must be level or

slightly lower in front to syphon

properly.

Inspect the tank assembly for

excessive lime deposits. Delime

as required.

The water pressure to the

brewer must be at least 20 psi

(138 kPa).

Timer must be set for at least

two minutes and fifteen seconds.

(A) Direction of flow arrow must

be pointing towards brewer.

(B) Remove the strainer/flow

control and check for obstruc-

tions. Clear or replace.

Inspect tank assembly for exces-

sive lime deposits. Delime as

required.

PROBLEM

PROBABLE CAUSE

REMEDY

41711.1 052009

Advertising