SERVICE (cont.)

TIMER (Early Models)

Location:

The timer is located inside the front of the trunk

on the upper right side of component bracket.

Test Procedure.

1. Disconnect the brewer from the power source.

2. Disconnect the polarized, three pin connector from

the brewer wiring harness.

3. With a voltmeter, check the voltage across sockets

P2 & P3 (white and white/red wires) of the female

connector when the "ON/OFF" switch is in the "ON"

position (upper). Connect the brewer to the power

source. The indication must be:

a) 120 volts ac for two wire 120 volt models and

three wire 120/240 volt models.

b) 200 to 240 volts ac on two wire 200 volt or 240

volt models.

4. Disconnect the brewer from the power source.

If voltage is present as described, proceed to #5.

If voltage is not present as described, refer to the

Wiring Diagrams and check the brewer wiring har-

ness.

5. Check the voltage across the sockets P1 & P2

(blue and white wires) of the female connector

with a voltmeter when the "ON/OFF" switch is in the

"ON" position (upper) and start switch pressed.

FIG. 24-1 TIMER TERMINALS

Connect the brewer to the power source. The

indication must be:

a) 120 volts ac for two wire 120 volt models and

three wire 120/240 volt models.

b) 200 to 240 volts ac for two wire 200 volt or 240

volt models.

6. Disconnect the brewer from the power source.

7. Reconnect the three pin connector from main

wiring harness to the timer.

If voltage is present as described, proceed to #8

If voltage is not present as described, refer to Wiring

Diagrams and check the start switch and brewer wir-

ing harness.

8. With a voltmeter, check the voltage across the

black and white wires when the "ON/OFF" switch

is in the "ON" position (upper) and the "START"

switch is pressed to the "START" position and

released. Connect the brewer to the power source.

The indication must be:

a) 120 volts ac for approximately 20 seconds for

two wire 120 volt models and three wire 120/240

volt models.

b) 200 to 240 volts ac for approximately 20 seconds

for two wire 200 volt or 240 volt models.

If voltage is present as described, the brew timer is

operating properly. Reconnect the polarized, three

pin connector.

If voltage is not present as described, replace the

timer.

Removal and Replacement:

1. Separate all connectors between the brewer wiring

harness and the timer.

2. Remove the one #8-32 screw securing timer to

component bracket.

3 Install new timer circuit board as described in Late

Model Timer section on the following pages.

4. Refer to Fig. 21 when reconnecting the wires.

5. Install the Timer Setting decal provided with the

replacement timer kit, below the schematic on the

inside of the front access panel.

6. Adjust the timer as required. Refer to Late Model

Timer section on the following pages.

EARLY STYLE

To Main Wiring Harness

To Solenoid Valve

41711.1 052009