SERVICE (cont.)

41711.1 052009

COIL/FAUCET
Location:

The coil for the faucet is located in the tank.

Operation:

Water inside the coil is separate from the brewing water

and is always under line pressure. Brewing water in

the tank heats the submerged coil. Use of a coil faucet

during a brew cycle will not cause short potting, but is

limited to 8-10 ounces of hot water before the cooler

water is passed through coil.

Removal and Replacement:

1. Disconnect the brewer from the power and water

sources.

2. Turn and remove aerator assembly from bottom of

faucet. Clean parts of any mineral buildup. Install

new gasket when reassembling.

3. Remove the bonnet nut and remove handle as-

sembly.

4. Remove the seat cup. Clean inside the faucet body

and install new seat cup.

Fig. 21-1 COIL/FAUCET

BONNET NUT

AERATOR

SEAT CUP

FAUCET BODY