High altitude installation – Schwank P40U Fenwal User Manual

Page 40

Advertising
background image

40

P40U-F / P40U-IF I&O Manual

IM101220

RD: MAY 2014

RL: 5A

ORIFICE CHART - ALTITUDE CONVERSION

MODEL NO

FOR USE AT ALTITUDES ABOVE (FEET)

Gas Orifice Drill Size / Part #

Supplied

USA Only

USA & CANADA*

0

2000

3000

4000

5000

6000

7000

8000

P40U / P40U-I NG

31 DMS

JS-0731-DM

3 mm

JS-0730-MM

32DMS

JS-0732-DM

32DMS

JS-0732-DM

33DMS

JS-0733-DM

34DMS

JS-0734-DM

7/64

JS-0731-IN

36DMS

JS-0736-DM

P40U / P40U-I LPG*

49 DMS

JS-0749-DM

50 DMS

JS-0750-DM

50 DMS

JS-0750-DM

50 DMS

JS-0750-DM

51 DMS

JS-0751-DM

51 DMS

JS-0751-DM

51 DMS

JS-0751-DM

52 DMS

JS-0752-DM

When this appliance is installed above the altitude stipulated below, the input must be de-rated

by 4% for each 1000 ft . If your local utility supplies gas with a de-rated heat content, no

orifice change is required in the heater . Check with your local utility regarding de-rating.

USA: The factory installed orifice for this appliance is approved for altitudes zero to

2000 feet above sea level. Above 2000 feet, refer to table below.

Canada: The factory installed orifice for this appliance is approved for altitudes zero to

4500 feet above sea level. When installed above 4500 feet, refer to the table below

27. HIGH ALTITUDE INSTALLATION

* Field Conversion Kit required to convert between fuel gas types:



Part number: JS-0555-XB P40U - Natural Gas to Propane Gas Conversion Kit



Part number: JS-0555-XA P40U - Propane Gas to Natural Gas Conversion Kit

Advertising