Schwank builderSchwank S100U User Manual

Page 3

Advertising
background image

3

S100-F / ITB-F I&O Manual

IM101230

RD: SEP 2014

RL: 11A

TABLE OF CONTENTS

TOPIC .........PAGE

INSTALLATION

IMPORTANT INFORMATION - READ FIRST

APPLICATION ..............................................4

HEATER EXPANSION ...........................5, 31

GAS CONNECTION ...............................5, 31

VENTING.................................................5, 26

START UP ‘SMOKE’ ....................................5

THERMOSTAT SETTING / COMFORT .......5

TUBE ‘GLOW’ ..............................................6

CLEARANCE TO COMBUSTIBLES ............6

Clearances Figure & Table ........................7

STACKING HEIGHT SIGN ..........................8

1. LABOR

REQUIREMENTS ...............................9

2. INSTALLATION IN AIRCRAFT HANGARS .....9

3. INSTALLATION: COMMERCIAL
GARAGES ........................................................9

4. INSTALLATIONS OTHER THAN

SPACE HEATING.............................................9

5. PRE-INSTALLATION

SURVEY......................10

6. MOUNTING

CLEARANCES...........................11

SERVICE CLEARANCE.................................11

HEATER

PLACEMENT GUIDELINES ...........12

7. SYSTEMS WITH 90° & 180° ELBOWS .........12

ELBOW KIT DIMENSIONS .……… .... …..13

8. SUSPENDING

THE SYSTEM........................14

9. BURNER & TUBE INSTALLATION

STRAIGHT TUBE SYSTEM........................15

‘U’ TUBE SYSTEM......................................17

SPECIAL COUPLING -

100,

175 & 200 Mbh..20

9.4 SESMIC RESTRAINT ....................................22

9.5 HIGH WIND RESTRAINT ...............................22

9.6 SEISMIC RESTRAINT ‘U’-TUBE....................23

10. REFLECTOR INSTALLATION ...................... 24

TOPIC ……...PAGE

12. FLUE VENTING ...............................................26

12A. MIN./MAX. SYSTEM LENGTHS ....................29

13. COMBUSTION AIR DUCT ...............................30

14. GAS SUPPLY ..................................................31

HEATER

EXPANSION.....................................32

FLEXIBLE GAS CONNECTION.......................33

15. ELECTRICAL AND THERMOSTAT.................34

16. HIGH ALTITUDE INSTALLATION ...................34

17. LIGHTING INSTRUCTIONS ...........................34

18. RECOMMENDED MAINTENANCE .................34

19. WIRING DIAGRAM: FENWAL DSI

24V or 120V THERMOSTAT ........................35

OR - HONEYWELL S87J DSI ........... 59 - 61
OR - CHANNEL MICRO 50N DSI ..... 62 - 65

19A. WIRING DIAGRAM: MULTIPLE HEATERS

PER THERMOSTAT ......36

20. FENWAL SEQUENCE OF OPERATION.........38

SPARK

IGNITER SET UP ...............................39

FENWAL DSI SERVICE CHECK ...................39

21-A TROUBLESHOOTING GUIDE: DSI ..............40

21-B TROUBLESHOOTING GUIDE: HEATER......41

22. START– UP / COMMISSIONING SHEET .......43

WARRANTY STATEMENT ...................BACK PAGE

DSI CONTROL ADDENDUM: PREVIOUS MODELS

HONEYWELL S87J DSI ............................ 59 - 61
CHANNEL MICRO 50N DSI ...................... 62 - 65

PRODUCT DIMENSIONS & DATA

23. BURNER / TUBE KIT ASSEMBLY CHART

23A. STRAIGHT TUBE SYSTEM ………….......45

23B. ‘U’ TUBE SYSTEM ………………………...46

24. MODEL INPUTS, DIMENSIONS, WEIGHTS ..47

INSTALLATION DIMENSIONS

………. ..48

25A. TURBULATORS - Straight Tube....................49

25B. TURBULATORS - ’U’- Tube...........................50

26. HIGH ALTITUDE & ORIFICE CHART...... 51 - 52

27. OPTIONAL ACCESSORIES..................... 53 - 56

28. BURNER PARTS LIST ............................ 57 - 58

29. TUBE SYSTEM PARTS LIST...........................59

S100 - S100U and ITB - ITBU SERIES

GAS FIRED INFRARED

LOW INTENSITY TUBE TYPE

Advertising
This manual is related to the following products: