SPARK IGNITER SET UP

Use the following diagram to check the Igniter gap. If the gap is incorrect all adjustments
should be made to the GROUND PRONG/PIN ONLY! DO NOT BEND THE IGNITER
PRONG!!!!

3/16”

1/4”

3/16” 1/4”

IF

this manual is in

8.5” x 11”

“booklet” format

(pages folded in half)

then use these bars

IF this manual is printed

8.5” x 11” “full page” format
use these bars

OR

ADJUST

SERVICE CHECKS

Flame current passes through the flame from
the sensor to ground. The minimum flame cur-
rent necessary to keep the system from lock-
out is 0.7 microamps. To measure flame cur-
rent, connect an analog DC microammeter to
the FC- FC+ terminals per figure at right.

Meter should read 0.7 µA or higher. If the me-
ter reads below “0” on scale, meter leads are
reversed. Disconnect power and reconnect
meter leads for proper polarity.

FC- FC+

Use Microamp

scale

Multipurpose Meter