S100-F / ITB-F I&O Manual

IM101230

RD: SEP 2014

RL: 11A

CHANNEL MICRO 50N: WIRING DIAGRAM: 120 VOLT THERMOSTAT CONTROL

(24V Thermostat—next page)

Each tube heater requires 120V, 60 HZ electrical power sized for 145VA. Maximum power
flow for internal 24V burner components is 21VA.

The heater must be electrically grounded in accordance with the National Electrical Code.
ANSI / NFPA 70 or current Canadian Electrical code CSA C22.1.

A maximum night set-back of 9°F (5°C) is recommended for optimum economy and comfort.
To maintain satisfactory comfort levels do not turn off the heating system over night/weekends.

Maximum Power Flow = 21VA

OTHER DSI’s: FENWAL SEE PAGE 35; HONEYWELL S87J - PAGES 59 - 61