Schwank builderSchwank S100U User Manual

Page 45

Advertising
background image

45

S100-F / ITB-F I&O Manual

IM101230

RD: SEP 2014

RL: 11A

23A. BURNER & TUBE KIT ASSEMBLY CHART MODELS S100 / ITB

MODELS S100 & ITB are approved for indoor commercial / industrial non-residential applica-

tions. For outdoor, wet and harsh environment applications refer to models SPW-JZ / IWP

(powder coated burner box) and/or STW-JZ / IW (stainless steel burner box).

BEFORE INSTALLING: ENSURE you have the CORRECT TUBE KIT(s) for the

BURNER INPUT

Tube Kit Gross

Weight (lbs)

80

120

120

170

210

165

165

120

165

Tube Length (ft)

10'

20'

20'

30'

40'

30'

30'

20'

30'

INPUT (Btuh)

TM-4510-

SX

TM-1020-

SX

TM-1420-

SX

TM-1430-

SX

TM-1040-

SX

TM-F030-

SX

TM-1030-

SX

TM-0020-

SX

TM-0030-

SX

10'

1

20'

1

20'

1

30'

1

20'

1

30'

1

40'

1

100,000

20'

1

30'

1

40'

1

50'

1+ 1

30'

1

40'

1

50'

1+ 1

40'

1

50'

1+ 1

60'

1+ 1

50'

1+

1

60'

1+

1

70'

1+

2

50'

1+

1

60'

1+

1

70'

1+

2

*NOTE: S100 Series tubes are NOT emissive coated

(except 10' x 45,000 & 20' x 100,000 Btuh tubes are emissive coated)

Stand-Alone tube kits require no additional tube kits.
Primary tube kits require at least one additional Secondary tube kit.
Secondary tube kit require a Primary tube kit.

S100 / ITB - TUBE KIT PART # & QUANTITY REQUIRED

Stand-Alone Kits

Primary Kits

+ Secondary Kits

80,000

110,000

45,000

60,000

175,000

200,000

130,000

155,000

USA - Stainless Steel Flexible Gas Connector

130,000 or less:
JL-0771-XX - 1/2”x24”

155,000 or more:
JL-0771-YY - 3/4”x36”

FLEXIBLE GAS CONNECTOR (Included in Burner Kit) - MUST INSTALL - see Section 13

CANADA - Type 1 Hose Gas Connector

130,000 or less:
JL-0771-RC - 1/2”x30”

155,000 or more:
JL-0771-RB - 3/4”x30”

Advertising