Changing the parameterising functions (continued) – Waldmann PULSE PIR version IV - with MFT, Typ II User Manual

Page 11

Advertising
background image

11

Operating Manual Light Control „PULSE HFMD / PULSE PIR - Vers. IV“

ENG

Actuation

Consequence

Changing the parameterising functions (Continued)

Fig. 3

LED 1 2 3 4 5 6

Fig. 6

Key I

Light

bar

Key II

Level 2 has been reached when

LEDs 1 + 2 are lit on the light

bar.

Level 3 has been reached when

LEDs 1 to 3 are lit on the light

bar.

Level 4 has been reached when

LEDs 1 to 2 are lit on the light

bar.

Changing the setting level

The setting level can be

loaded by pressing both

keys simultaneously for

10 seconds.

Press both keys for 5

seconds each as often as

necessary for reaching the

desired setting level.

n x

Release both keys

Once the desired setting level has

been reached, the setting of the

first function (x.1) is shown on the

light bar as soon as the keys are

released (LED 1 is lit or flashes

dark green).