Setting function 2.3 – Waldmann PULSE PIR version IV - with MFT, Typ II User Manual

Page 26

Advertising
background image

26

Operating Manual Light Control „PULSE HFMD / PULSE PIR - Vers. IV“

ENG

Loading setting level 2

Actuation

Display

Light bar LED 1 (dark green)

Parameterisation mode ON

Function 2.3

Special function

Light bar LED 3 (yellow)

Function 2.3

Changing the function from ON to OFF or vice versa

Setting function 2.3

LED changes from constantly lit

to flashing or vice versa:

- constant = Function ON

- flashing

= Function OFF

Loading the parameterisation mode

Press both keys again

for 5 seconds

Light bar LEDs 1+2

Level 2

Press key II twice

Press both keys

for at least 10 seconds

2 x

Special function

The special function cannot be

used.

The function cannot be changed.

n x

Press key I as often as

necessary for reaching

the desired value

Advertising