Changing function (example) – Waldmann PULSE PIR version IV - with MFT, Typ II User Manual

Page 15

Advertising
background image

15

Operating Manual Light Control „PULSE HFMD / PULSE PIR - Vers. IV“

ENG

Example

How to load and change the func-

tion x.y is shown using the func-

tion 2.5 "Continuous mode" as an

example.

a) To load the parameterisation

function:

press both keys for at least

10 seconds

b) To load setting level x:

press both keys (x-1) times

for 2 seconds

c) To load function y:

press key II (y-1) times

d) To change the function:

press key I

e) To leave the parameterisation

mode:

do not press any key for at

least 10 seconds.

Loading setting level 2

Press both keys

for at least 10 seconds

Actuation

Display

Light bar LED 1 (dark green)

Parameterisation mode ON

Function 2.5

Continuous mode

Light bar LED 5 (light red)

Function 2.5

Changing the function from ON to OFF or vice versa

LED changes from constantly lit

to flashing or vice versa:

- constant = Function ON

- flashing

= Function OFF

Loading the parameterisation mode

Press both keys again

for 5 seconds

Light bar LEDs 1+2

Level 2

Press key II 4 times

Changing the parameterising functions (Example)

4 x

n x

Press key I as often as

necessary for reaching

the desired value

Advertising
This manual is related to the following products: