Operating Manual Light Control „PULSE HFMD / PULSE PIR - Vers. IV“

ENG

Loading setting level 2

Actuation

Display

Light bar LED 1 (dark green)

Parameterisation mode ON

Function 2.6

Parameter setting protection

Light bar LED 6 (dark red)

Function 2.6

Changing the function from ON to OFF or vice versa

Setting function 2.6

LED changes from constantly lit

to flashing or vice versa:

- constant = Function ON

- flashing

= Function OFF

Press key II 5 times

Loading the parameterisation mode

Light bar LEDs 1+2

Level 2

Press both keys again

for 5 seconds

Press both keys

for at least 10 seconds

5 x

n x

Press key I as often as

necessary for reaching

the desired value

Parameter setting protection

Function for activating the param-

eter setting protection (required for

final inspection)

By default, the function is set to

"OFF".

When the function is switched on,

a factory reset will not overwrite

the set parameters. The parameter

setting of the electronic ballast

units will be carried out.

The function can be changed on
- Lights equipped with HFMD

sensor

- Lights equipped with PIR sensor