Operating Manual Light Control „PULSE HFMD / PULSE PIR - Vers. IV“

ENG

Loading setting level 1

Actuation

Display

Light bar LED 1 (dark green)

Parameterisation mode ON

Function 1.3

Burn-In function

Light bar LED 3 (yellow)

Function 1.3

Changing the function from ON to OFF or vice versa

Setting function 1.3

LED changes from constantly lit

to flashing or vice versa:

- constant = Function ON

- flashing

= Function OFF

Press key II twice

Loading the parameterisation mode

Release both keys

Light bar LED 1 (dark green)

Level 1

Press both keys

for at least 10 seconds

2 x

n x

Press key I as often as

necessary for reaching

the desired value

Burn-in function

Function for burning in the lamps

By default, the function is set ex

works to "OFF". When the burn-in

function is activated, the following

functions are disabled:
- Light control
- Presence function
- Dimming function

After 100 operating hours, the

function is automatically set to

"OFF" again, i.e., the light can now

be operated without restrictions.

The function can be changed on
- Lights equipped with HFMD

sensor
- Lights equipped with PIR sensor