Parámetros de grupo avanzados, Español-10 – Rockwell Automation 22A PowerFlex 4 Quick Start FRN 6.xx User Manual

Page 60

Advertising
background image

Español-10

Parámetros de Grupo Avanzados

No. Parámetro

Mín/Máx

Pantalla /Opciones

Valor

Predeterminado

A051

A052

[Sel. ent digt 1]

Terminales de E/S 05

[Sel. ent digt 2]

Terminal de E/S 06

0/26

0 = “No se usa”

1 = “Acel/Decel 2”

2 = “Avan/impuls”

3 = “Fallo Aux”

4 = “Frec presel”

5 = “Local”

6 = “Puerto Com”

7 = “Borrar Fallo”

8 = “ParoRamp,CF”

9 = “ParInerc,CF”

10 = “ParInjCC,CF”

11 = “ImpulsAvance”

12 = “ImpulsRetroc”

13 = “EntCtrl10V”

14 = “EntCtrl20mA”

26 = “Inver Anlg”

4

A055 [Sel. Sal. Pulsos]

0/21

0 = “Listo/Fallo”

1 = “EnFrecuencia”

2 = “MotorMarcha”

3 = “Retroceso”

4 = “Sobrcarg mtr”

5 = “Reg Ramp”

6 = “Sobre Frec”

7 = “Sobre Cte”

8 = “Sobre V CC”

9 = “AgotReintent”

10 = “Sobre V Anlg”

20 = “ContParám”

21 = “Fallo no rec”

0

A056 [Nivel Sal Pulsos]

0.0/9999

0.1

0.0

A067 [Tiempo acel. 2]

0.0/600.0 segs

0.1 segs

20.0 segs

A068 [Tiempo decel. 2]

0.1/600.0 segs

0.1 segs

20.0 segs

A069 [Frec Interna]

0.0/240.0 Hz

0.1 Hz

60.0 Hz

A070

A071

A072

A073

[Frec presel 0]

( (1)

[Frec presel 1]

[Frec presel 2]

[Frec presel 3]

0.0/240.0 Hz

0.1 Hz

0.0 Hz

5.0 Hz

10.0 Hz

20.0 Hz

(1)

Para activar [Frec presel 0] establezca P038 [Referencia Veloc] en la opción 4.

A078 [Frecuencia test]

0.0/[Frecuencia Máx.] 0.1 Hz

10.0 Hz

A079 [Impulsos Ace/Dec]

0.1/600.0 segs

0.1 segs

10.0 segs

A080 [Tiempo freno CC]

0.0/90.0 segs

0.1 segs

0.0 segs

A081 [Nivel freno CC]

0.0/(Intens. Var

× 1.8) 0.1 Amps

Amps

× 0.05

A082 [Sel resisten FD]

0/99

0 = Inhabilitado

1 = Res RA Norml

2 = SinProtecc

3-99 = CiclTrab %

0

A083 [% curva-S]

0/100%

1%

0% (Inhabilitado)

A084 [Refuer. arranque]

1/14

Ajustes en % de tensión base.

8

7 (Variadores

de 5 HP)

Par Variable

Par Constante

1 = “30.0, VT”

5 = “0.0, no IR” 10 = “10.0, CT”

2 = “35.0, VT”

6 = “0.0”

11 = “12.5, CT”

3 = “40.0, VT”

7 = “2.5, CT”

12 = “15.0, CT”

4 = “45.0, VT”

8 = “5.0, CT”

13 = “17.5, CT”

9 = “7.5, CT”

14 = “20.0, CT”

A088 [Tensión máxima]

20/Volts nomin var.

1 V CA

Volts nomin var.

A089 [Lím. Corriente]

0/(Intens. Var

× 1.8)

0.1 Amps

Amps

× 1.5

A090 [Selec. SC Motor]

0/2

0 = “NoDesclasif”

1 = “DesclasifMín”

2 = “DesclasifMáx”

0

A091 [Frecuencia PWM]

2.0/16.0 kHz

0.1 kHz

4.0 kHz

A092 [Int. rearme auto]

0/9

1

0

A093 [Retrd reinic aut]

0.0/300.0 segs

0.1 segs

1.0 segs

A094 [Inic al encender]

0/1

0 = “Inhabilitado”

1 = “Habilitado”

0

A095 [Inver Deshab.]

0/1

0 = “Rev Habilit”

1 = “Rev Inhabil”

0

A096 [Act. mrch. Vuelo]

0/1

0 = “Inhabilitado”

1 = “Habilitado”

0

A097 [Compensación]

0/3

0 = “Inhabilitado”

1 = “Eléctrico”

2 = “Mecánico”

3 = “Ambos”

1

A098 [Disparo Corr. SW]

0.0/(Intens. Var

× 2)

0.1 Amps

0.0 = (Inhabilitado)

A099 [Factor Proceso]

0.1/999.9

0.1

30.0

A100 [Borrar fallo]

0/2

0 = “Listo/Inactv”

1 = “Restab fallo”

2 = “BorrarBuffer”

0

A101 [Bloqueo Programa]

0/1

0 = “Desbloqueado”

1 = “Bloqueado”

0

A102 [Sel pto. Prueba]

0/FFFF

1 Hex

400

Estado de Entrada de Ent.

Digital 1 (Terminal de E/S 05)

Estado de Entrada de Ent.

Digital 2 (Terminal de E/S 06)

Fuente de

Frecuencia

Parámetro Acel./Decel. utilizado (2)

0

0

[Frec presel 0]

[Tiempo acel. 1] / [Tiempo decel. 1]

1

0

[Frec presel 1]

[Tiempo acel. 1] / [Tiempo decel. 1]

0

1

[Frec presel 2]

[Tiempo acel. 2] / [Tiempo decel. 2]

1

1

[Frec presel 3]

[Tiempo acel. 2] / [Tiempo decel. 2]

(2)

Cuando una entrada digital se establece en “Acel/Decel 2” y la entrada está activa, dicha entrada anula los ajustes en

esta tabla.

Consulte el Manual del Usuario del PowerFlex 4 para más información sobre parámetros.

Advertising