Uitgebreide-groepparameters, Nederlands-10 – Rockwell Automation 22A PowerFlex 4 Quick Start FRN 6.xx User Manual

Page 72

Advertising
background image

Nederlands-10

Uitgebreide-groepparameters

Nr.

Parameter

Min/Max

Display/Opties

Default

A051

A052

[Sel digit ing 1]

I/O aansluit-

terminal 05

[Sel digit ing 2]

I/O aansluit-

terminal 06

0/26

0 = “Niet gebruikt”

1 = “Acc 2 & dec 2”

2 = “Joggen”

3 = “Fout aux”

4 = “Preset freq”

5 = “Lokaal”

6 = “Comm.poort”

7 = “Fout wissen”

8 = “Ac/dcStpFtws”

9 = “VrlpStp ftws”

10 = “DCInjStpFtws”

11 = “Vooruit jog”

12 = “Achtruit jog”

13 = “Reg 10 V in”

14 = “Reg 20 mA in”

26 = “Anal invert”

4

A055 [Sel relais-uitg]

0/21

0 = “Gereed/fout”

1 = “Op freq”

2 = “Mtr in bedrf”

3 = “Achteruit”

4 = “Motoroverbel”

5 = “Reg acc/dec”

6 = “Te hoge freq”

7 = “Te hg stroom”

8 = “Te hoge DC V”

9 = “Pogingen op”

10 = “Te hg anal V”

20 = “Param reg”

21 = “Nt-hrst fout”

0

A056 [Niv relais-uitg]

0,0/9999

0,1

0,0

A067 [Accel.tijd 2]

0,0/600,0 sec

0,1 sec

20,0 sec

A068 [Decel.tijd 2]

0,1/600,0 sec

0,1 sec

20,0 sec

A069 [Interne freq]

0,0/240,0 Hz

0,1 Hz

60,0 Hz

A070

A071

A072

A073

[Preset freq 0]

(1)

[Preset freq 1]

[Preset freq 2]

[Preset freq 3]

0,0/240,0 Hz

0,1 Hz

0,0 Hz

5,0 Hz

10,0 Hz

20,0 Hz

(1)

Om [Preset freq 0] te activeren stelt u P038 [Snelheidsref] in op optie 4.

A078 [Jog freq]

0,0/[Max frequentie]

0,1 Hz

10,0 Hz

A079 [Jog Accel/Decel]

0,1/600,0 sec

0,1 sec

10,0 sec

A080 [DC remtijd]

0,0/90,0 sec

0,1 sec

0,0 sec

A081 [DC remniveau]

0,0/(A van drive

× 1,8) 0,1 A

A

× 0,05

A082 [Sel DB weerstand]

0/99

0 = Uit

1 = Norm RA wrst

2 = Gn bescherm

3-99 = % van cyclus

0

A083 [% S-kromme]

0/100%

1%

0% (Uit)

A084 [Start boost]

1/14

Instellingen in % van basisspanning.

8

7 (drives van

3,75 kW)

Variabel koppel

Constant koppel

1 = “30,0; VT”

5 = “0,0; geen IR” 10 = “10,0; CT”

2 = “35,0; VT”

6 = “0,0”

11 = “12,5; CT”

3 = “40,0; VT”

7 = “2,5; CT”

12 = “15,0; CT”

4 = “45,0; VT”

8 = “5,0; CT”

13 = “17,5; CT”

9 = “7,5; CT”

14 = “20,0; CT”

A088 [Max spanning]

20/Nominale V

1 VAC

Nominale V

A089 [Stroomgrens 1]

0/(A van drive

× 1,8) 0,1 A

A

× 1,5

A090 [Sel mtr overbel]

0/2

0 = “Geen derate”

1 = “Min derate”

2 = “Max derate”

0

A091 [PWM frequentie]

2,0/16,0 kHz

0,1 kHz

4,0 kHz

A092 [Poging aut hstrt]

0/9

1

0

A093 [Vertr aut hstrt]

0,0/300,0 sec

0,1 sec

1,0 sec

A094 [Start bij powerup]

0/1

0 = “Uit”

1 = "Vrijgegeven”

0

A095 [Achteruit uit]

0/1

0 = “A.uit vrijg”

1 = “A.uit uit”

0

A096 [Vlg strt vrijgeg]

0/1

0 = “Uit”

1 = “Vrijgegeven”

0

A097 [Compensatie]

0/3

0 = “Uit”

1 = “Elektrisch”

2 = “Mechanisch”

3 = “Beide”

1

A098 [Uitsch stroom SW]

0,0/(A van drive

× 2) 0,1 A

0,0 (Uit)

A099 [Procesfactor]

0,1/999,9

0,1

30,0

A100 [Fout wissen]

0/2

0 = “Gereed/Idle”

1 = “Fout reset”

2 = “Buffer wis”

0

A101 [Program vergrend]

0/1

0 = “Ontgrendeld”

1 = “Vergrendeld”

0

A102 [Sel testpunt]

0/FFFF

1 Hex

400

Ingangstoestand van digitale ing 1

(I/O aansluitterminal 05)

Ingangstoestand van digitale ing 2

(I/O aansluitterminal 06)

Frequentiebron Gebruikte parameter Accel/decel (2)

0

0

[Preset freq 0]

[Accel.tijd 1] / [Decel.tijd 1]

1

0

[Preset freq 1]

[Accel.tijd 1] / [Decel.tijd 1]

0

1

[Preset freq 2]

[Accel.tijd 2] / [Decel.tijd 2]

1

1

[Preset freq 3]

[Accel.tijd 2] / [Decel.tijd 2]

(2)

Wanneer een digitale ingang op “Accel 2 en Decel 2” wordt ingesteld, en de ingang actief is, gaat de

ingang aan de instellingen in deze tabel voorbij.

Zie de Gebruikershandleiding van de PowerFlex 4 voor meer informatie over parameters.