Rockwell Automation 20D-RES-A0 PowerFlex 700S Resolver Feedback Option User Manual
Page 14
14
Resolver Feedback Option Card for PowerFlex® 700S Drives
Recommended Cable
Rockwell Automation strongly recommends the use of Reliance Electric
417900-207CG cable for installation, or an equivalent cable that meets
these specifications:
• 3 Twisted Pairs, 80°C, 300V
• Chrome FPR Jacket, Plenum Rated
• Conductor Size: 18 AWG
• Twists Per Inch: 2-3 twists per inch of wire lay per pair
• Capacitance Per Pair: not to exceed 30 pF per foot +/- 0.3 pF as read on a
GEN_RAD Model 1658 RLC Digibridge or equivalent
• Capacitance Diference Pair to Pair: not to exceed 0.6 pF per foot as read
on a GEN_RAD Model 1658 RLC Digibridge or equivalent
• Resistance per 1000 Feet: 17.15Ω +/- 10%
• Inductance per 1000 Feet: 0.13 mH +/- 10% as read on a GEN_RAD
Model 1658 RLC Digibridge or equivalent
• Insulation Thickness: 0.008 in.
• Conductor Stranding 16/30
• Jacket Thickness: 0.018 in.