Rockwell Automation 20D-RES-A0 PowerFlex 700S Resolver Feedback Option User Manual
Page 8
Advertising
![background image](/manuals/577013/8/background.png)
8
Resolver Feedback Option Card for PowerFlex® 700S Drives
Step 6: Wiring the Resolver
Feedback Option Card to a
Resolver
Terminal block P1 contains connection points for a resolver. This terminal
block resides on the Resolver Feedback Option card
.
TIP: Remember to route wires through the sliding access panel at the
bottom of the Control Assembly.
Terminal
Signal
Description
8
REF HIGH
Positive Reference signal
7
SHIELD
Connection point for resolver cable
shield
6
REF LOW
Negative Reference signal
5
SIN HIGH
Positive Sine signal
4
SHIELD
Connection point for resolver cable
shield
3
SIN LOW
Negative Sine signal
2
COS HIGH
Positive Cosine signal
1
COS LOW
Negative Cosine signal
12
34
5
6
7
8
Advertising