Viewing and clearing events – Rockwell Automation 25B PowerFlex 525 Embedded EtherNet/IP Adapter User Manual
Page 114

114
Rockwell Automation Publication 520COM-UM001B-EN-E - March 2013
Chapter 8
Troubleshooting
Viewing and Clearing Events
The adapter has an event queue to record significant events that occur in the
operation of the adapter. When such an event occurs, an entry consisting of the
event’s numeric code and a timestamp is put into the event queue. You can view
the event queue using the PowerFlex 22-HIM-A3/-C2S HIM or Connected
Components Workbench.
The event queue can contain up to 32 entries, which are stored in RAM—
making the event queue volatile, meaning a power cycle will clear the event queue.
If the event queue becomes full, a new entry replaces the oldest entry. Only a
power cycle, event queue clear operation, or the corruption of the RAM group
containing the event queue will clear the event queue contents.
Many events in the event queue occur under normal operation. If you encounter
unexpected communications problems, the events may help you or Allen-Bradley
personnel troubleshoot the problem. The following events may appear in the
event queue:
F708
F712
F716
F720
F724
Drv 0 Feedback
Drv 1 Feedback
Drv 2 Feedback
Drv 3 Feedback
Drv 4 Feedback
In Multi-drive mode, this is the feedback being received from drive 0.
In Single-drive mode, this is the feedback of the drive at the time.
F725
EN Rx Overruns
A count of the number of receive overrun errors reported by the embedded EtherNet/IP
interface.
F726
EN Rx Packets
A count of the number of Ethernet packets that the adapter has received.
F727
EN Rx Errors
A count of the number of receive errors reported by the Ethernet hardware.
F728
EN Tx Packets
A count of the number of Ethernet packets that the adapter has sent.
F729
EN Tx Errors
A count of the number of transmit errors reported by the Ethernet hardware.
F730
EN Missed IO Pkt
A count of the number of incoming I/O connection packets that the adapter did not
receive.
F731
DSI Errors
A count of the number of DSI errors.
IMPORTANT
The diagnostic parameters for the dual port EtherNet/IP adapter option card
cannot be viewed using the HIMs. Use Connected Components Workbench
instead.
Embedded EtherNet/IP Adapter Diagnostic Parameters
No.
Name
Description
Adapter Events
Code
Event
Description
Adapter Events
0
No Event
Text displayed in an empty event queue entry.
1
Normal Startup
Power is applied to the adapter.
2
Manual Reset
The adapter was reset.
3
Watchdog T/O Flt
The software watchdog detected a failure and reset the adapter.
4
App Updated
The adapter application firmware was flash updated.
5
Boot Updated
The adapter boot firmware was flash updated.
6
EEPROM Sum Flt
The EEPROM checksum/CRC is incorrect, which limits adapter functionality. Default
parameter values must be loaded to clear this condition.
DSI Events