Compactlogix example ladder logic, Controller tags – Rockwell Automation 25B PowerFlex 525 Embedded EtherNet/IP Adapter User Manual
Page 66

66
Rockwell Automation Publication 520COM-UM001B-EN-E - March 2013
Chapter 5
Using the I/O
CompactLogix Example Ladder Logic Program Using a Drive Add-On Profile for Logic Command/
Reference
Creating Ladder Logic Using the RSLogix 5000/Logix Designer Generic
Profile
Controller Tags
When you add the drive to the I/O configuration (see
RSLogix 5000/Logix Designer automatically creates generic (non-descriptive)
controller tags. In this example program, the following controller tags are used.
CompactLogix Controller Tags for Drive Generic Profile Ladder Logic Program Example
Copy File
Source
Dest
Length
Speed_Reference
PowerFlex_52X_Drive:O.FreqCommand
1
COP
Command_Stop
PowerFlex_52X_Drive:O.DriveLogicRslt_Stop
Command_Start
PowerFlex_52X_Drive:O.DriveLogicRslt_Start
Command_Jog
PowerFlex_52X_Drive:O.DriveLogicRslt_Jog
Command_Clear_Faults
PowerFlex_52X_Drive:O.DriveLogicRslt_ClearFault
Command_Forward_Reverse
PowerFlex_52X_Drive:O.DriveLogicRslt_Forward
Command_Forward_Reverse
PowerFlex_52X_Drive:O.DriveLogicRslt_Reverse