Data format for a read and write of a parameter – Rockwell Automation 160 DEVICENET (DN1) MODULE FRN 1-2.XX User Manual
Page 54

Publication 0160-5.5 - September 1997
Using 160-DN1 with DeviceNet Scanner
6-19
Programming the SLC to Run
Explicit Messaging (Continued)
Data Format for a Read and Write of a Parameter
Request Data for Read of Parameter 30 (Accel Time)
N10 address
address
0
1
2
3
4
5
6
7
8
9
N10:0
0101
0006
0E01
00B3
0001
001E
0000
0000
0000
0000
N10:10
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
N10:20
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
N10:30
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
Response Data for Read of Parameter 30
N11 address
address
0
1
2
3
4
5
6
7
8
9
N11:0
0101
0002
8E01
00B3
0000
0000
0000
0000
0000
0000
N11:10
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
N11:20
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
N11:30
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
Request Data for Write to Parameter 30
N10 address
address
0
1
2
3
4
5
6
7
8
9
N10:0
0101
0008
1001
00B3
0001
001E
0001
0000
0000
0000
N10:10
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
N10:20
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
N10:30
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
Response Data for Write to Parameter 30
N11 address
address
0
1
2
3
4
5
6
7
8
9
N11:0
0101
0000
9001
0000
0000
0000
0000
0000
0000
0000
N11:10
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
N11:20
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
N11:30
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000