Rockwell Automation 284G ArmorStart - User Manual User Manual
Page 260

C-10
Bulletin 284G CIP Information
Instance 161 is the default input (produced) assembly for the Bulletin
280G/281G Distributed Motor Controller
Table C.28 Instance 161 — Default Produced Standard Distributed Motor.
Instance 163 is the standard input (produced) assembly with Network
Outputs for the Bulletin 280G/281G Distributed Motor Controller
Table C.29 Instance 163 — Standard Produced Starter with Network Outputs
and ZIP CCV.
Inverter Type Distributed Motor Controller Input (Produced)
Assemblies
Instance 165 is the default input (produced) assembly for Inverter
Type Distributed Motor Controllers
Table C.30 Default Produced Inverter Type Distributed Motor Controller.
➊
Refers to control brake contactor status.
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
0
—
140M
On
—
Ready
Running
Rev
Running
Fwd
—
Tripped
1
—
—
User In
5
User In
4
User In 3
User In 2
User In 1
User In 0
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
0
140M On
Ready
Running
Rev
Running
Fwd
Warning
Tripped
1
User In
5
User In
4
User In 4
User In 3
User In 2
User In 1
2
Net Out
8
Net Out
7
Net Out
6
Net Out
5
Net Out 4
Net Out 3 Net Out 2 Net Out 1
3
Logic
Enable
Stat
Net Out
15
Net Out
14
Net Out
13
Net Out
12
Net Out
11
Net Out
10
Net Out 9
4
ZIP Device Value Key (Low)
5
ZIP Device Value Key (High)
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
0
At
Reference
140M On
Net Ctl
Status
Ready
Running
Rev
Running
Fwd
Alarm
Tripped
1
Reserved
Contactor 1
➊
User In
5
User In
4
User In 3
User In 2
User In 1
User In 0
2
Output Frequency (Low) (xxx.x Hz)
3
Output Frequency (High) (xxx.x Hz)