Rockwell Automation 1391ES AC Servo Controller User Manual

Page 62

Advertising
background image

Transformers and Shunt Regulators

Chapter 9

9-60

ATTENTION: Proper derating must be applied to the
manufacturers nominal resistor power ratings when using these
in external shunt configurations. Consult the resistor
manufacturer for recommended derating. Failure to comply
could result in personal injury and/or equipment damage from
an overheated resistor.

!

Shunt Fusing

Shunt regulator fusing is provided with all of the 1391B-ES controllers.
The fuse is in series with the resistor and used to protect the resistor against
short circuits. The shunt fuse is located on top of the controller near the
circuit breaker for 15 and 22.5A controllers. External resistors for 22.5A
and 45A controllers are supplied with a fuse which must be mounted
external to the controller (see Appendix A for mounting dimensions). Refer
to Table 9.C for further shunt fuse information.

Table 9.C
Shunt Fuse Information

Controller
Rating

15A

22.5A

22.5A

45A

Fuse Loca-
tion

Top Panel

Top Panel

External

External

Fuse Type

Buss KLM-10 or equivalent

Buss FNM-6.25 or equivalent

Buss KTK-15 or equivalent

Buss KLM-20 or equivalent

Important: Repeated overvoltage tripping can be an indication that the
shunt fuse has malfunctioned.

Advertising