Rockwell Automation 1336T Function Block Prog. Manual, Series A/B User Manual
Page 32

1–20
Getting Started
1336 FORCE — 5.9 August 1995
— Link the SR FF Block Reset to the Limit Min
Limit Flag
BTW
Data File
N57:0
0000
8F04
8102
8401
0
0
0
0
0
0
0
1
2
3
4
5
6
7
8
9
7. Link the SR FF block Reset (block 2, node 1) to the Limit Min
Limit Flag (block 1, node 4).
8. Toggle bit I:00/00 to initiate the block transfer routine which will
download the link.
9. Verify that the write was successful. If N57:101 = 0F04
hex
(Block
Transfer Read data), there are no errors.
— Link the Multiplexer Block Sel 0 to the SR FF
Output 1
BTW
Data File
N57:0
0000
8F04
8403
8202
0
0
0
0
0
0
0
1
2
3
4
5
6
7
8
9
10.Link the Multiplexer block Sel 0 (block 3, node 4) to the SR FF
Output 1 (block 2, node 2).
11. Toggle bit I:00/00 to initiate the block transfer routine which will
download the link.
12.Verify that the write was successful. If N57:101 = 0F04
hex
(Block
Transfer Read data), there are no errors.
— Link the Rate Limiter Input to the Multiplexer
Output 1
BTW
Data File
N57:0
0000
8F04
8004
8603
0
0
0
0
0
0
0
1
2
3
4
5
6
7
8
9
13.Link the Rate Limiter block Input (block 4, node 0) to
Multiplexer Output 1 (block 3, node 6).
14.Toggle bit I:00/00 to initiate the block transfer routine which will
download the link.
15.Verify that the write was successful. If N57:101 = 0F04
hex
(Block
Transfer Read data), there are no errors.