Step 7 - Wire the Control Signal Terminal Block
7-3
1329I-5.0 Integrated Drive/Motor — January, 1999
Figure 7.2
Typical Control Signal Connections for Standard Units
Table 7.2
User Wiring for Standard Units
➊ An external 0 to 10 volt DC or 4 to 20 mA speed reference source can be connected. See Section 7.5.3
for more information.
➋ The jumper between terminals 7 and 11 must be removed when wiring the Function Loss input. See
Section 7.1 for more information.
Signal
Refer to Section
Function Loss
7.1
Analog Input
7.2
Relay Control Output
7.3
RPM/Percent Load Display
7.4
Speed Reference (select one)
Preset Speed
7.5.1
Speed Potentiometer
7.5.2
External Speed Reference (0 – 10V DC or 4 – 20 mA)
7.5.3
Start
7.6
Stop
7.6
Forward/Reverse
7.7
Reset
7.8