7 wiring forward / reverse control, 8 wiring reset control, Wiring forward / reverse control -10 – Rockwell Automation 1329I Integrated AC Drive/Motor, Series A User Manual
Page 34: Wiring reset control -10
 
7-10
Step 7 - Wire the Control Signal Terminal Block
1329I-5.0 Integrated Drive/Motor — January, 1999
7.7
Wiring Forward / Reverse Control
Important:
This applies to standard units only.
The Forward / Reverse input (the connection between terminals 13 and 14) defines the 
requested direction of motor rotation. If the input is open, the requested direction is 
forward. Switching the Forward / Reverse input causes the motor to ramp to rest and 
then accelerate in the opposite direction. Note that the 1329I unit is shipped with the 
forward direction defined as CCW shaft rotation as viewed from the motor shaft end.
Figure 7.13 shows the Forward / Reverse control wiring for the 1329I unit. If you disable 
(lock out) reverse using the setup DIP switch, do not wire to this input because the drive 
ignores any transition on this input. Refer to the setup DIP switch description in 
Chapter 8
Figure 7.13
Forward / Reverse Control Wiring
7.8
Wiring Reset Control
Important:
This applies to standard units only.
An open-to-closed transition at the Reset input (control terminal 15) clears a fault once 
the appropriate corrective action has been taken. After clearing the fault, you must 
reassert the Start command in order to restart the unit.
Wire a normally-open (N.O.) push-button between control terminals 15 and 13 as shown 
in Figure 7.14. Refer to Chapter 11, Diagnostics and Troubleshooting, for more 
information on faults.
Figure 7.14
Reset Control Wiring
12
13
14
15
24 Volts DC
Forward/Reverse
Rev
Fwd
12
13
14
15
16
24 Volt DC
Reset