I/o specifications, Approvals and standards compliance, Analog inputs – Rockwell Automation 1329I Integrated AC Drive/Motor, Series A User Manual
Page 63: Analog output, Relay output (1 form a n.o. contact)

Technical Specifications
A-5
1329I-5.0 Integrated Drive/Motor — January, 1999
I/O Specifications
Important:
All signals are isolated from the incoming 3-phase power.
Analog inputs
0 to 10 V
Input impedance: 50 k
Ω
Resolution: 0.11%
4 to 20 mA
Input impedance: 250
Ω
Resolution: 0.14%
Analog output
0 to 10 V
Minimum load resistance: 2 k
Ω
Resolution: 0.4%
Logic inputs (Stop, Start, Reset, Fwd/Rev, RPM/%Load, Function
Loss, Preset Speed)
24 VDC sourcing inputs
Maximum input voltage: 28.8 VDC
Input current @ 24 VDC: 10 mA
Maximum OFF state voltage: 5 VDC
Minimum ON state voltage: 15 VDC
Relay output (1 form A N.O. contact)
Maximum current (resistive or inductive): 1 A
Minimum current: 10 mA
Maximum voltage: 28 VDC, 250 VAC
Approvals and Standards Compliance
Approvals:
Designed to meet these standards:
FCC Class A and B, ICE 146-1-1, VDE 0871 and VDE 0875
UL
®
LIST
ED 966X
IND CONT EQ
UL508C
UL
®
LIST
ED 966X
IND CONT EQ
C
CSA 22.2
EMC Directive 89/336
LV:
EN 50178, EN 60204