Specifications – Rockwell Automation 1751 SynchLink 4-Port Splitter Block Installation Instructions User Manual

Page 14

Advertising
background image

14 SynchLink 4-port Splitter Block

Publication 1751-IN002A-EN-P - March 2001

Specifications

Communication Rate

5M bit/s

Splitter Block Power Consumption

5V dc input from 1751-SLBA
0.300 A @ 5.1V dc

Environmental Conditions

(1)

(1)

This product must be mounted within a suitable system enclosure to prevent personal injury resulting from accessibility to
live parts. The interior of this enclosure must be accessible only by the use of a tool. This industrial control equipment is
intended to operate in a Pollution Degree 2 environment, in overvoltage category II applications, (as defined in IEC
publication 664A) at altitudes up to 2000 meters without derating.

Operating Temperature

0ºC - 60ºC

Storage Temperature

-40ºC - 85ºC

Relative Humidity

5 to 95%, 0ºC - 60ºC non-condensing

Shock

Operating

30g peak acceleration, 11 (

±

1)ms pulse width

Non-operating

50g peak acceleration, 11 (

±

1)ms pulse width

Vibration

Tested 5 g @ 10 - 500Hz per IEC 68-2-6

Fiber Optic Cable

Fiber Type

200/230 micron HCS (Hard Clad Silica)

Fiber Termination Type

Versalink V-System

Assemblies

Cable assemblies can be ordered from Allen-Bradley, catalog
number 1403-CFxxx (xxx = length in meters); or from Lucent
Technologies, Specialty Fiber Technologies division.

Maximum Length

300 meters

Minimum Length

1 meter

Agency Certifications
When product is marked:

Listed Industrial Control Equipment

Certified Process Control Equipment

Certified Class I, Division 2, Group A, B, C, D

Marked for all applicable directives

marked for all applicable acts

N223

Advertising