Autobaud -15 – Rockwell Automation 1747-PBASE BASIC Development Software Programming Manual User Manual
Page 115
![background image](/manuals/579254/115/background.png)
Publication 1746-PM001A-US-P
Communicating with the Module 9-15
Figure 9.4 RS-232 Terminal Setup Menu
Autobaud
This menu selection automatically finds the baud rate of the module connected to
your personal computer’s currently configured RS-232 port. Note that Autobaud
searches for the baud rate but does not modify the data bits, stop bits, parity, or
port number. These selections must be correctly configured to match those of the
module before Autobaud can successfully find the baud rate.
File Setup Display deBug Exit
↓↑→←
to Edit
+------------------SETUP----------------------+
|Autobaud |===============================+
|General (file names, etc.)... | |
|Terminal... | |
|com Port settings (baud rate, etc.)... <AltP>| |
|Colors | |
|saVe setup | |
+-----------------Cancel<ESC>-----------------+ |
| |
| |
| |
| |
+------------------------------------------------------------------------------+
HELP<F1>|MENU<F2>|EXIT<F3>| COM1 1200 8 1 N|LOG CLOSED|ANSI | 06-12-91 1:15pm