31

ArmorBlock 16 Input Module

Publication 1792-5.3 – October 1996

1,1,1,0,0,0,0,0,0;

$ Not Used

$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
$$$$$$$$$$
Param6 =

$ Input 2 value

0,

$ reserved

6,

$ Link Path Size

”20 08 24 02 30 03”,

$ Link Path to Input 2 value attribute.

0x0030,

$ No support for settable path, scaling, or scaling
$ links.
$ Value is gettable only.
$ Enumerated strings are not supported.

8,

$ Data Type – unsigned short int

1,

$ Data Size – (in bytes)

”Input 2 Value”,

$ Parameter Name

””,

$ Units String

$$$$$$$$$$ Help string $$$$$$$$$$$

”This parameter is the current value of Input 2.”,
0,1,0,

$ Min, Max, and Default values

1,1,1,0,0,0,0,0,0;

$ Not Used

$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
$$$$$$$$$$
Param7 =

$ Input 3 value

0,

$ reserved

6,

$ Link Path Size

”20 08 24 03 30 03”,

$ Link Path to Input 3 value attribute.

0x0030,

$ No support for settable path, scaling, or scaling
$ links.
$ Value is gettable only. Enumerated strings are not
$ supported.

8,

$ Data Type – unsigned short int

1,

$ Data Size – (in bytes)

”Input 3 Value”,

$ Parameter Name

””,

$ Units String

$$$$$$$$$$ Help string $$$$$$$$$$$

”This parameter is the current value of Input 3.”,
0,1,0,

$ Min, Max, and Default values

1,1,1,0,0,0,0,0,0;

$ Not Used

$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
$$$$$$$$$$
Param8 =

$ Input 4 value

0,

$ reserved

6,

$ Link Path Size

”20 08 24 04 30 03”,

$ Link Path to Input 4 value attribute.

0x0030,

$ No support for settable path, scaling, or scaling
$ links.
$ Value is gettable only. Enumerated strings are not
$ supported.

8,

$ Data Type – unsigned short int

1,

$ Data Size – (in bytes)