Controller logging Chapter 3

Log file format

The following table lists the information that is contained in the controller log

file.

Content

Description

Format

Time

Controller's GMT time

MMM-DD-YY HH:MM:SS
24-hour time

Entry

Entry Description (defined in Entry List

section)

User Name

User's login ID

Windows domain name with display name

if available

Workstation Name

User's computer name

Computer Name

FactoryTalk ID

User's FactoryTalk login ID

Alphanumeric characters

Extended Information

Entry specific information (defined in Entry
List section)

Change Detection Audit

Value

1

Changes that the controller detected in the

Audit value

(1) Version 20 or later. See

Change detection in Logix Designer Application on

page 51

.

The log file is formatted in UTF-16, and has a file extension of .txt. Double-

clicking the file opens it in Notepad on most systems. However, since it is

formatted as Tab Separated Values (TSV), you can also open it in a spreadsheet

application, like Microsoft Excel.

The following screen is an example of the log file in Notepad.

Tip: For version 20 and later, a column for the Audit Value changes is included in the log file.

The following screen is an example of the log file in Excel.

Rockwell Automation Publication 1756-PM015F-EN-P – October 2014