Change detection Chapter 4

Tip: Rockwell recommends using the DINT[2] data type to avoid limitations when working with LINT data types in

Rockwell Automation controllers.

You can use the Message Configuration dialog box to read or write to the

ChangesToDetect attribute through CIP Generic Messages. For complete

information on how to access data using an MSG instruction, refer to the

Logix5000 Controllers Messages Programming Manual

, publication

1756-

PM012

.

Use the following settings to configure the ChangesToDetect attribute using the

Message Configuration dialog box.

If you want to:

In this property

Type or select

Set controller events monitored
for changes

Message Type

CIP Generic

Service Type

Changes to Detect Set

Source

tag_name of type DINT[2] or LINT 1
This tag represents a bit mask of the changes monitored for
the controller.

Destination

Leave blank

Get controller events monitored

for changes

Message Type

CIP Generic

Service Type

Changes to Detect Get

Source

Leave blank

Destination

tag_name of type DINT[2] or LINT 1
This tag represents a bit mask of the changes monitored for
the controller.

AuditValue

Use the Get System Value (GSV) instruction to read the AuditValue attribute

programmatically.

You can use the Message Configuration dialog box to read the AuditValue

attribute through CIP Generic Messages. For complete information on how to