Rockwell Automation Logix5000 Controllers Major, Minor, and I/O Faults Programming Manual User Manual

Page 34

Advertising
background image

Chapter 1 Major faults

Type

Code

Cause

Recovery Method

18

9

An Absolute Position Recovery (APR) fault has occurred and the
absolute position of the axis cannot be recovered.

To determine the corrective action, see the APR Fault attributes to determine the cause
of the fault.
For more information about the APR Fault attributes, see the

Integrated Motion on the

Ethernet/IP Network Configuration and Startup User Manual

, publication

MOTION-

UM003

.

18

10

An Absolute Position Recovery (APR) fault has occurred and the
absolute position of the axis cannot be recovered.
This fault is indicated when a manufacturer-specific APR fault
has occurred.

To determine the corrective action, see the APR Fault - Mfg attributes to determine the
cause of the fault.
For more information about the APR Fault - Mfg attributes, see the

Integrated Motion on

the Ethernet/IP Network Configuration and Startup User Manual

, publication

MOTION-

UM003

.

18

128

A fault specific to the Guard Motion safety function has

occurred.
This fault is applicable only when a drive with Guard Safety
functionality is used.

To determine the corrective action, see the Guard Motion attributes and Guard Status

bits to determine the cause of the fault.
For more information about the Guard Motion attributes and Guard Status bits, see the

Integrated Motion on the Ethernet/IP Network Configuration and Startup User Manual

,

publication

MOTION-UM003

.