2706-UM001A-US-P

5-2

Run Mode

Run Mode - Serial Operation

To enter the serial triggering run mode:

Move the DIP switch (SW1-1) to the UP (serial trigger) position.

This immediately switches the DL5 from the edit to run mode. The
operation of the serial port changes from programming to serial message
triggering.

Note: Any message edits or menu entries are terminated when the DIP
switch position is changed.

After entering the serial trigger mode, the standard startup screens are
displayed followed by the autorun message. The DL5 will then interpret any
serial data as a message trigger command.

To exit the serial triggering run mode:

Move the DIP switch (SW1-1) to the Down (configure) position.

This switches the DL5 from the run to edit mode. The operation of the
serial port changes from serial message triggering to programming. The
following is displayed after exiting the serial triggering mode:

With the DIP switch in the Configure position, any serial data is
interpreted as a menu or edit command.

1

2

UP

Serial Trigger
Not Used

SW1

1

2

DOWN

Configure
Not Used

SW1