Fuse Replacement

The Bulletin 6157 Industrial Monitor is equipped with two AC line fuses
housed in the IEC connector (2.5A 250V). To access the fuses, you must
remove the rear cover of the unit.

ATTENTION: Fuse replacement requires work in
areas that can present dangerous voltages. Always
disconnect the AC power cord and wait one minute
before attempting fuse replacement. Replace the rear
cover before restoring power to the monitor.

To replace the fuses:

1.

Disconnect the power cord and remove all other cables attached to
the monitor.

2.

Remove the four screws that secure the rear panel of the monitor
using a Philips screwdriver. Refer to the following figure.

Figure 7
Fuse Replacement

3.

Remove the rear panel to expose the rear section of the AC input
connector. Pull off the plastic cap, situated at the rear of the AC
connector, to expose the fuses.