Panel mounting guidelines – Rockwell Automation 6157 Industrial 20 inch Monitors User Manual

Page 7

Advertising
background image

Industrial 20" CRT Monitor

7

Publication 6157-5.1

Panel Mounting Guidelines

Observe the following precautions before installing the unit in a panel:

Confirm that there is adequate space behind the panel. Remember to
allow extra space (3 in. (76.2 mm) behind and 1 in. (25.4 mm) below
and on each side) for air circulation.

Confirm that the cabinet is deep enough to accommodate the
monitor's depth while providing rear clearance for airflow. A cabinet
with depth of 23.11 in. (587 mm) is sufficient.

Take precautions so that metal cuttings do not enter any components
that are already installed in the panel.

Supporting panels should be at least 14 gauge to ensure proper
sealing against water and dust and to provide proper support. The
mounting hardware supplied accommodates panels up to 0.25 in.
(6.35 mm) thick.

Note:

Supporting panels must be cut and drilled to
specifications prior to installation.

ATTENTION: Failure to follow these warnings may
result in personal injury or damage to the panel
components.

Advertising