Start-up information messages display in a specific sequence on the terminal during
startup and typically display for a few seconds. These messages do not require that
you perform any action.

Message #

Message

Description

37

Video Initialized

Configures and initializes the graphics video system.

30

Watchdog Test

Tests the watchdog circuitry to verify system integrity.

1

RAM Test

Tests the RAM memory.

31

Stuck Key

Checks the integrity of the function key hardware.

31.5

Stuck Touch

Checks the integrity of the touch screen hardware.

32

Battery Test

Checks the integrity of the battery hardware.

2.5

Registry Search

Locates and loads the most recent, valid registry. Multiple copies of
the registry are maintained. If power is lost during a registry update, a
valid registry is available the next time power is applied to the
terminal.

2

Image Search

Checks for a new OS firmware upgrade on the external CompactFlash
card and the serial port.

50

External CF

Transfers a new OS firmware upgrade from the external
CompactFlash card to the terminal. Message may display for several
minutes.

23

Internal CF

Programs the OS firmware just downloaded into the internal flash
memory. Message may display for several minutes.

24

CRC Check

Checks the integrity of the OS firmware.

28

Starting System

Launches the operating system (OS).

29

System Check ###

Internal file system integrity check (### is percent progress indicator).

29.1

System Check

Internal file system integrity check disabled. Contact technical
support.