6 Kinetix 2000 Power Rail
Publication 2093-IN004A-MU-P - December 2006
Kinetix 2000 Power Rail Dimensions
Mount the Power Rail
The Kinetix 2000 power rail comes in several lengths. Power rails will support one integrated 
axis module, additional axis modules, and a shunt module (catalog numbers 2093-AC05-MPx, 
2093-AMPx, 2093-AM0x, and 2093-ASP06). Additional open slots must have a slot filler 
module (2093-PRF) installed to provide continuity for control signals and system power. 
Follow these steps to mount a Kinetix 2000 power rail.
1.
Lay out the position for your power rail in the enclosure.
For panel layout recommendations, refer to the Kinetix 2000 Multi-axis Servo Drive 
User Manual, publication 2093-UM001. Mounting hole dimensions are provided in 
the figure and table. 
2.
Attach the power rail to the cabinet.
The recommended mounting hardware is M4 metric bolts.
Catalog 
Number
Power Rail 
Axis 
Dimension, Approx.
A
mm
(in.)
B
mm
(in.)
C
mm 
(in.)
2093-PRS1 1
90.0
(3.54)
N/A
N/A
2093-PRS2 2
130.0 (5.12) 40.0 (1.58) N/A
2093-PRS3 3
170.0 (6.69) 80.0 (3.15) N/A
2093-PRS4 4
210.0 (8.27) 120.0 (4.72) N/A
2093-PRS5 5
250.0 (9.84) 160.0 (6.30) N/A
2093-PRS7 7
330.0 (12.99) 240.0 (9.45) 120.0 (4.72)
2093-PRS8S 8
410.0 (16.14) 320.0 (12,60) 160.0 (6.30)
ATTENTION
These procedures assume you have prepared your panel and understand 
how to bond your system. 
Refer to the Kinetix 2000 Multi-axis Servo Drive User Manual, 
publication 2093-UM001, for detailed instructions on how to ground and 
bond your power rail.