Module compatibility – Rockwell Automation 2094-xxxx Kinetix 6200 and Kinetix 6500 Control Module Installation Instructions User Manual

Page 3

Advertising
background image

Kinetix 6200 and Kinetix 6500 Control Modules 3

Rockwell Automation Publication 2094-IN012C-EN-P - August 2013

Module Compatibility

Kinetix 6000 IAM/AM modules and Bulletin 2094 power modules with Kinetix 6200 control
modules are completely compatible and can be used together on the same Bulletin 2094 power
rail.

Drive/Control Module Compatibility

IMPORTANT

Kinetix 6200 (sercos) and Kinetix 6500 (EtherNet/IP) control modules are not compatible and
cannot be used on the same Bulletin 2094 power rail.

IAM Module/
Control Module

IAM Power Module

2094-

xMxx-S

Kinetix 6000
AM Module

2094-BM

xx-M

AM Power Modules

Kinetix 6200
Control Module

Kinetix 6500
Control Module

2094-

xCxx-Mxx-S

Kinetix 6000 (sercos)

N/A

Fully compatible

Fully compatible

Not compatible

2094-SE02F-M00-S

x

Kinetix 6200 (sercos)

2094-BC

xx-Mxx-M

2094-EN02D-M01-S

x

Kinetix 6500 (EtherNet/IP)

Not compatible

Not compatible

Fully compatible

Advertising