Rockwell Automation 2094-xxxx Kinetix 6200 and Kinetix 6500 Control Module Installation Instructions User Manual
Page 5

Kinetix 6200 and Kinetix 6500 Control Modules 5
Rockwell Automation Publication 2094-IN012C-EN-P - August 2013
3. Align the control module mounting studs so they engage with the power module hooks.
4. Pivot the control module toward the power module to engage the signal connectors and
guide pins.
5. Tighten the captive screw.
6. Repeat
step 2
through
step 5
to mount a control module onto each power module
installed on your Bulletin 2094 power rail.
Mounting Hook
(right side)
IAM or AM Power Module
(IAM power module is shown)
Mounting Stud
(right side)
Left-side mounting stud and hook are
hidden from view.
Bulletin 2094 Control Module
(Kinetix 6200 control
module is shown)
IAM or AM Power Module
(IAM power module is shown)
Mounting Stud and
Hook Engaged
(right side)
Guide Pins
Straddling Tongue
Guide Pin Alignment on
Either Side of Tongue
Left-side mounting stud and hook are
hidden from view.
Bulletin 2094 Control Module
(Kinetix 6200 control
module is shown)
Captive Screw
(apply 1.1 N•m (10 lb•in) torque)
IAM or AM Power Module
(IAM power module is shown)
Bulletin 2094 Control Module
(Kinetix 6200 control
module is shown)