4.

Carefully remove the monitor from its packaging. Avoid damaging
the monitor gasket.

Tip: It will be easier to install the monitor if you support it with a shelf
or other support adjusted to the appropriate height.

5.

Insert the monitor in the panel cutout from the front. Do not damage
the threaded mounting studs as you position the monitor.

6.

Secure the unit with the lock nuts and washers provided. Tighten
evenly to 24 inch-pounds of torque.

Important:

To ensure a proper seal, be sure to install a washer and
nut on each of the 18 mounting studs.

ATTENTION: Mounting nuts must be tightened to a
torque of 24 inch-pounds to provide panel seal and
avoid potential damage. Rockwell Automation
assumes no responsibility for water or chemical
damage to the monitor or other equipment within the
enclosure due to improper installation.

7.

Remove the protective adhesive sheet from the screen of the
Industrial Monitor. The sheet is designed to prevent scratching of
the polycarbonate screen protector or the optional touchscreen
during shipping and installation. It should be removed before use.