Installing the touchscreen driver software – Rockwell Automation 6159 Industrial 17 inch CRT Monitors, Series B User Manual

Page 31

Advertising
background image

Industrial 17" CRT Monitor

31

Publication 6159-5.1

Interconnecting wiring to the host serial port connection is shown in the
following table.

Table E
Touchscreen Interface

Monitor

(DCE Device)

Host (DTE Device)

DE-9 (Female)

Signal Description

DE-9 (Male)

DB-25 (Male)

1

Not Connected (DCD)

1

8

2

Transmit Data (TXD)

2

3

3

Receive Data (RXD)

3

2

4

Data Terminal Ready (DTR)

4

20

5

Common Signal Return (SG)

5

7

6

Not Connected (DSR)

6

6

7

Request To Send (RTS)

7

4

8

Clear To Send (CTS)

8

5

9

Not Connected

9

22

Installing the Touchscreen Driver Software

To install the touchscreen driver software correctly, obtain the following
information about the host hardware:

The COM port in use for the touchscreen. Ensure that the RS-232
cable is properly installed between the monitor port and the host’s
COM port.

The baud rate at which the controller is operating. You will need to
match the baud rate at the COM port. The controller baud rate is
factory set at 9600.

Note:

If you are using older touchscreen software, you may be
prompted for the type of touchscreen controller being used.
The 6159 uses the following controllers:

Resistive: MicroTouch model SMT3V.

Capacitive: MicroTouch model SMT3R.