Clearances – Rockwell Automation 2711-L6Cxx_B6Cxx PanelView 600 Terminals Installation Instructions User Manual
Page 7
Advertising
PanelView 600 Terminals 7
Publication 2711-IN010G-EN-P - February 2009
Clearances
Allow adequate space for mounting, air flow, maintenance, and for installing a
memory card, and legend inserts.
TERMINAL CUTOUT
Use Full Size
Template shipped with
Terminal
Front View
Side, Top and Bottom Clearances
116 mm
(4.57 in.)
91 mm
(3.60 in.)
6.9 mm
(0.27 in)
Approximately
220 mm (8.65 in.) is
required to insert and
remove a memory card
with the memory card
retainer.
card
Memory Card Retainer
Leave 51 mm (2.0 in.)
for Mounting and Wiring Connections
Leave 25 mm (1 in.)
for Mounting and Air Flow
Leave 38 mm (1.5 in.) for Mounting,
Air Flow and Legend Insert
Leave 51 mm (2 in.)
for Mounting and Air flow
Back Clearance
Top View