Clearances

Allow adequate space for mounting, air flow, maintenance, and for installing a
memory card, and legend inserts.

TERMINAL CUTOUT
Use Full Size
Template shipped with
Terminal
Front View

Side, Top and Bottom Clearances

116 mm
(4.57 in.)

91 mm
(3.60 in.)

6.9 mm
(0.27 in)

Approximately
220 mm (8.65 in.) is
required to insert and
remove a memory card
with the memory card
retainer.

card

Memory Card Retainer

Leave 51 mm (2.0 in.)
for Mounting and Wiring Connections

Leave 25 mm (1 in.)
for Mounting and Air Flow

Leave 38 mm (1.5 in.) for Mounting,
Air Flow and Legend Insert

Leave 51 mm (2 in.)
for Mounting and Air flow

Back Clearance
Top View